The SC1000 is a SCADA ready pump controller designed to perform level control. The variety of control options available through the setup menu may be used to customize the controller for a number of specific applications. The SC1000 controller operates the pumps based on selected setup values and the liquid level signal. The level input level source is menu selectable for either a 4-20 mA pressure transducer, or a 10 point conductance probe. The SC1000 controller alternates the pumps, performs lag pump delays, and provides high and low level alarms.
(3) The SC100 controller is a low cost, simple to use duplex controller with an analog input for level control. The controller contains four output relays; for pump 1 and pump 2 call, and for high and low alarms. A regulated 24 V DC power supply is provided for powering the pressure transducer circuit. The controller contains a red LED bar graph to display the level, and red LED’s to display Pumps 1 and 2 call, and the high and low level alarms. There are additional red LED’s for the level settings and level simulation, which are turned on by depressing the Setting Select pushbutton. The controller also has a 10 second power-up delay, and a 5 second lag pump delay to prevent the turning on of one or both of the pumps immediately after a power ...
The solid state DUPLEXER controller will automatically control and alternate any duplex system while providing the user with a visual indication of its input/output status. Time delayed outputs, internal latching, internal alternator and fail safe operation insure reliable operation even in the event of external signal device failures. Alternation will always occur when the lowest input device is de-activated. A high level alarm output is provided to activate a visual or audible alarm device.
Plug In model is UL Listed only when used with a SD12 socket.
The Intrinsically Safe Duplexer, ISD, is a low cost, intrinsically safe duplex pump controller for water and wastewater lift station applications.
The controller's intrinsically safe float switch inputs allow safe handling of float switches by lift station personnel. UL associated apparatus provides intrinsically safe circuits for use in Class I, Groups A, B, C, D Class II, Groups E, F, G and Class III - Hazardous locations.
(25) The SC2000 is a Scada ready pump controller designed to perform level control in a wide range of lift station applications. It operates the pumps based on the selected setup values and the analog wet well level signal from pressure transducer or other device. It alternates the pumps, performs lag pump delay(s), and provides high and low level alarms. It has a variety of control options available in the setup menu that may be used to customize the controller for a specific application. The SC200 comes standard with 18 discrete inputs. Optional I/O is available for VFD speed control and for additional telemetry inputs.
Motor Protection Electronics, Inc. -
2464 Vulcan Rd. - Apopka, FL 32703 -
Tel: 407-299-3825 - Fax: 407-294-9435