Item # LPR-1 Level Probe Relay




    Print Printable Page  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

Level-Probe-Relay

larger image
Level Probe Relay
The Level Probe Relay senses liquid level and provides a relay output for controlling a pump or level alarm. The unit has two inputs, an ON and an OFF, for connection to two electrodes of a conductance probe. All setup is easily done using the DIP switches on the unit.

When used for a level alarm the ON and OFF inputs may be connected to the same electrode on the probe, or the ON input may be used by itself. When used for pump control the ON and OFF inputs are typically connected to two different level probe electrodes to provide a latching function.

The unit has two pump control modes, Pump Down (empty a tank) and Pump Up (fill a tank) (see table below). When in the Pump Down mode and both inputs detect liquid, the unit energizes the relay and keeps it energized until the level drops to the point where the OFF input no longer detects liquid. When in the Pump Up mode and both inputs detect no liquid, the unit energizes the relay and keeps it energized until the level rises to where the OFF input detects liquid.

The Sensitivity of the unit must be set for the type of liquid being detected (see the Dip Switch table). The unit provides a 10 second power up delay to prevent a pump from being turned on too soon after a power interruption. An adjustable ON Delay is provided for use as a lag pump delay. The adjustable OFF Delay is provided so that the unit may be used to provide timed off, backup pump control. (See the Dip Switch table for ON and OFF delay settings.)



 Specifications  

UL File No.

#E101681

Supply Voltage (AC)

120 V

Supply Voltage Tolerance

± 10%

Supply Phase

Single

Supply Frequency

50/60 Hz

Max. Power Consumption

3.8 VA

Relay Type

DPDT

Sensor Output Voltage

± 12 V Square Wave

Sensor Output Current

± 1.2 mA max (per sensor)

Operating Temperature

-40 to 60 °C

Storage Temperature

-45 to 85 °C

Enclosure Material

Poly Carbonate

Base Material

Phenolic

Plug-In Socket

SD12-PC